One of the topics we're frequently asked is "what are zinc whiskers?" This perplexing issue is extremely common and is found in data centers and computer rooms of all sizes.
Tags: computer room air conditioning, CRAC, data center cooling
The size and shape of a data center can impact the ability of Computer Room Air Conditioning (CRAC) systems to adequately cool the heat loads. Larger rooms will typically require a greater number of CRAC units due to limitations on air delivery of the units. So, although a single unit may have the BTU (British thermal unit) capacity to cool a given load, it may be unable to effectively deliver the cool air if the load is spread out in a large room resulting in inadequate data center cooling.
Tags: data center cooling
Data centers and server rooms require large amounts of energy to operate and the push now is to reduce the use of energy in data centers - green initiatives. Additional encouragement is coming from utilities throughout the United States in the form of energy efficiency rebates and incentives.
Tags: data center cooling, data center design, data center energy management
Ensure Uptime - Perform Load Bank Testing on Data Center Generators
Posted by Paul Golden on Nov 2, 2009
Data Centers and other critical facilities rely heavily on power to give it the ability to perform. Testing the power in your facility is something that should be done because you need to know your backup power in your data center is strong enough to handle even the heaviest of loads.
Tags: Data Center, preventive maintenance, emergency backup generator, data center generators
Preventive data center maintenance is one of the key approaches to protecting a facility through detection of potential points of failure before the deficiency initiates a system-wide malfunction, this is key for mission critical facilities. What if the output of your UPS or DC power system was interrupted for even a few seconds? This would cause a huge disruption in your critical load, which in turn could cost your business serious downtime and money.
Tags: data center power
UPS Systems Provide Power Protection for Data Centers - Size them Correctly
Posted by Kim Otte on Oct 19, 2009
A power outage, however brief, can cause most data centers and businesses to grind to a halt. As a result, information, productivity and profit can be lost. Using an Uninterruptible Power Supply (UPS) is the easiest way to provide secure power to protect your mission critical systems.
Tags: data center protection
Welcome to Electronic Environments Corporation's New Data Center Blog
Posted by Michael Kingsley on Oct 19, 2009
Engineering, construction and maintenance has become an increasingly complex undertaking in today's data centers. Our blog is to promote an open exchange of ideas, questions and recommendations relating to these issues in data centers, computer rooms and other mission critical facilities.
Tags: Data Center, data center design